Safety maintenance of air compressor electrical system: wiring inspection+grounding protection+motor maintenance
HMM
2025-12-05 17:24:29
0order
- Wiring inspection:
Regularly check whether the power and control line connectors are loose or oxidized, and promptly tighten or replace the wiring terminals if any problems are found;
Check whether the contacts of the contactor and relay are burned. If there are burn marks, they need to be polished or replaced to avoid poor contact.
Grounding protection:
Ensure that the equipment grounding device is intact, the grounding resistance is ≤ 4 Ω, and the grounding wire is not broken or loose;
Regularly test the grounding continuity to avoid electric shock accidents caused by leakage.
Motor maintenance:
Cleaning: Clean the dust on the motor casing every 100 hours to ensure proper heat dissipation;
Bearing lubrication: Add lubricating grease (lithium based grease) to the motor bearings every 2000 hours;
Insulation test: Test the insulation resistance of the motor every year. If the resistance value is ≥ 1M Ω, it is qualified. If it is lower than the standard, maintenance is required.