- Maintenance of air-cooled models:
Cleaning: Clean the dust and cotton wool on the surface of the heat sink every 50 hours, and use a high-pressure water gun (low-pressure mode) to rinse to avoid blocking the heat dissipation channel;
Fan inspection: Every 100 hours, check whether the fan blades are deformed, whether the motor is running normally, and add lubricating grease when the bearings are short of oil;
Environmental requirements: Ensure that a ventilation space of at least 30cm is reserved around the equipment to avoid heat sources from approaching.
Maintenance of water-cooled models:
Water quality treatment: Use softened water to avoid scale deposition; Add water stabilizer every 3 months to prevent corrosion and scaling;
Cooler cleaning: Disassemble the cooler every 6 months, soak it in descaling agent for cleaning (or rinse with high-pressure water), and remove the scale inside the pipes;
Pipeline inspection: Check whether the cooling water inlet and outlet pipelines are unobstructed, valves and water pumps are running normally, and there is no leakage.